Google Search.....

Custom Search

E&M – Earth & Mouth Signalling

E&M – Earth & Mouth is a type of line signaling that uses separate leads, called the "E" lead and "M" lead.There are NEAR & FAR ends.The near end sends a signal to the far end by applying -48 vdc to the "M" lead, which results in a ground being applied to the far end's "E" lead ie the near-end wanted to call the far end. When -48 vdc is applied to the far end "M" lead, the near-end "E" lead is grounded. When the near-end "E" lead is grounded, the far end is calling and wanted your ear.




8 Wires of E and M signaling


There are different E&M standards, with 2,4.6 & 8 wires.
  • 2 wire E&M is technically same with a normal CO trunk.2 wire E&M means 2 wires ie one pair for signaling E&M and 2 wires ie one pair for Voice.-Total of 2 pairs
  • In 4 wire E&M, 2 wires ie 1 pair is used for receiving voice and 2 wires ie 1 pair for transmitting voice and one pair for signalling.-Total 3 pairs